<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SSA5000A Series Archives - Siglent</title>
	<atom:link href="https://siglentna.com/operating-tips/spectrum-analyzers/ssa5000a-series/feed/" rel="self" type="application/rss+xml" />
	<link>https://siglentna.com/operating-tips/spectrum-analyzers/ssa5000a-series/</link>
	<description>Siglent Technologies America, Inc</description>
	<lastBuildDate>Tue, 16 Jan 2024 06:58:46 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://siglentna.com/wp-content/uploads/2025/04/cropped-512X512.1-32x32.png</url>
	<title>SSA5000A Series Archives - Siglent</title>
	<link>https://siglentna.com/operating-tips/spectrum-analyzers/ssa5000a-series/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SSA5000A IQA&#038;IFO Operation Manual</title>
		<link>https://siglentna.com/operating-tip/ssa5000a-iqaifo-operation-manual/</link>
		
		<dc:creator><![CDATA[daisy]]></dc:creator>
		<pubDate>Tue, 16 Jan 2024 06:58:46 +0000</pubDate>
				<guid isPermaLink="false">https://siglentna.com/?post_type=operating-tips&#038;p=41821</guid>

					<description><![CDATA[<p>1. IQ Acquisition IQ acquisition is similar to zero-span measurement in Swept SA, where the input signal is displayed as I/Q data results. It is commonly used for measuring digital modulated signals and supports exporting IQ data to txt files for users to perform data demodulation and analysis. The IQA window presents the I and &#8230; <a href="https://siglentna.com/operating-tip/ssa5000a-iqaifo-operation-manual/">Continued</a></p>
<p>The post <a href="https://siglentna.com/operating-tip/ssa5000a-iqaifo-operation-manual/">SSA5000A IQA&#038;IFO Operation Manual</a> appeared first on <a href="https://siglentna.com">Siglent</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h6><strong>1. IQ Acquisition</strong></h6>
<p style="padding-left: 40px;">IQ acquisition is similar to zero-span measurement in Swept SA, where the input signal is displayed as I/Q data results. It is commonly used for measuring digital modulated signals and supports exporting IQ data to txt files for users to perform data demodulation and analysis. The IQA window presents the I and Q signal waveforms, depicting the voltage changes over time. The I signal is represented by the yellow trace, while the Q signal is represented by the purple trace. I/Q views provided in spectrum measurements enables users to examine complex components of the same signal without the need to modify settings or measurements.</p>
<p><strong>1.1 Amplitude</strong></p>
<p style="padding-left: 40px;">Configuring the amplitude parameters of the analyzer makes the display of the measured signal visually appealing and minimizes measurement errors. By adjusting these parameters, the signal can be displayed in the current window in an easily observable format. Once the amplitude parameters have been modified, the measurement process will commence anew.</p>
<p style="padding-left: 40px;"><strong>1.1.1  Ref Value</strong></p>
<p>         The reference line may be positioned top, center or bottom of the marker by setting a reference value.1.2 Scale/Div</p>
<p style="padding-left: 40px;">Configuring the unit for each vertical scale division in the logarithmic display can be done by either manually setting the value or enabling automatic scaling, which is determined by the measured results.</p>
<p style="padding-left: 40px;"><strong>1.1.2  Attenuation</strong></p>
<p style="padding-left: 40px;">Based on the magnitude of the input signal, the user configures the corresponding RF front-end attenuator and amplifier to avoid distortion when presenting large input signals and reduce noise when dealing with small input signals.</p>
<p><strong>1.2 Sweep</strong></p>
<p style="padding-left: 40px;"><strong>1.2.1 Sweep/Measure</strong></p>
<p style="padding-left: 40px;">The analyzer can be set to perform a single Scan/Measure or continuous Scan/Measure by selecting the ‘Single’ or ‘Continue’ mode.</p>
<p style="padding-left: 40px;"><strong>1.2.2 Restart</strong></p>
<p style="padding-left: 40px;">Restarting the current scan or measurement is achieved by initiating a re-Scan/Measure, particularly if the scan parameters have been modified.</p>
<p><strong>1.3 Meas Setup</strong></p>
<p style="padding-left: 40px;">Click on the ‘Measurement Settings’ menu and select appropriate averaging parameters, center frequency, measurement time, and sampling rate based on the specific parameters of the acquired IQ signal.</p>
<p style="padding-left: 40px;"><strong>1.3.1 Avg|Hold Number</strong></p>
<p style="padding-left: 40px;">Averaging|Hold count N represents the counter when the trace type is set to ‘Average’. In a single measurement (Single) and any valid trace type set to ‘Average’, the scan will stop when the counter reaches N.</p>
<p style="padding-left: 40px;">A higher (Average|Hold) count can reduce the influence of noise or other random signals, highlighting the stable characteristics of the signal.</p>
<p style="padding-left: 40px;"><strong>1.3.2 Averaging</strong></p>
<p style="padding-left: 40px;">Enable or disable the averaging calculation option for measurement results.</p>
<p style="padding-left: 40px;"><strong>1.3.3 Avg Mode</strong></p>
<p style="padding-left: 40px;">Choose the control type for the averaging function. This determines the averaging operation after reaching the specified data acquisition count (average count).</p>
<p style="padding-left: 40px;">Options include:</p>
<p style="padding-left: 40px;">      -Exponential (Exp): The measurement averages using a specified number of exponentially weighted averages. The average value is displayed at the end of each scan.</p>
<p style="padding-left: 40px;">      &#8211; Repeat: The measurement resets the average counter each time the specified number of averages is reached.</p>
<p style="padding-left: 40px;"><strong>1.3.4 Center Freq</strong></p>
<p style="padding-left: 40px;">Ensure that the set center frequency matches the frequency of the IQ signal, otherwise the IQ waveform will not be displayed properly.</p>
<p style="padding-left: 40px;"><strong>1.3.5 Meas Time</strong></p>
<p style="padding-left: 40px;">Set the time for signal acquisition, which represents the recording duration of the waveform. Due to memory limitations, the maximum measurement time may decrease when using a higher sampling rate.</p>
<p style="padding-left: 40px;"><strong>1.3.6 Sample Rate</strong></p>
<p style="padding-left: 40px;">Set the sampling rate for signal acquisition, indicating the number of IQ pairs collected per second. Choose an appropriate sampling rate based on the specific IQ signal to avoid distortion in the acquired IQ signal.</p>
<p><strong>1.4 Operation Demonstration</strong></p>
<p style="padding-left: 40px;">1）Input the 16QAM signal through the RF port of SSA5000A.</p>
<p style="padding-left: 40px;">2）Use the IQ Acquisition to observe the I/Q signal waveform of the signal:</p>
<p style="padding-left: 40px;">(1)Click <span style="text-decoration: underline;">Mode/Meas</span>→<span style="text-decoration: underline;">Spectrum Analyzer(SA)</span>→<span style="text-decoration: underline;">IQ Acquisition</span>→<span style="text-decoration: underline;">Replace/Add</span>→<span style="text-decoration: underline;">OK</span>.</p>
<p style="padding-left: 40px;"><img fetchpriority="high" decoding="async" class="alignnone wp-image-41824" src="https://siglentna.com/wp-content/uploads/2024/01/S-1-1024x640.png" alt="" width="600" height="375" srcset="https://siglentna.com/wp-content/uploads/2024/01/S-1-1024x640.png 1024w, https://siglentna.com/wp-content/uploads/2024/01/S-1-300x188.png 300w, https://siglentna.com/wp-content/uploads/2024/01/S-1-768x480.png 768w, https://siglentna.com/wp-content/uploads/2024/01/S-1-600x375.png 600w, https://siglentna.com/wp-content/uploads/2024/01/S-1.png 1280w" sizes="(max-width: 600px) 100vw, 600px" /></p>
<p style="padding-left: 40px;">(2) Click <span style="text-decoration: underline;">FREQ</span>, configure the center frequency corresponding to the IQ signal.</p>
<p style="padding-left: 40px;"><img decoding="async" class="alignnone wp-image-41825" src="https://siglentna.com/wp-content/uploads/2024/01/S-2-1024x640.png" alt="" width="600" height="375" srcset="https://siglentna.com/wp-content/uploads/2024/01/S-2-1024x640.png 1024w, https://siglentna.com/wp-content/uploads/2024/01/S-2-300x188.png 300w, https://siglentna.com/wp-content/uploads/2024/01/S-2-768x480.png 768w, https://siglentna.com/wp-content/uploads/2024/01/S-2-600x375.png 600w, https://siglentna.com/wp-content/uploads/2024/01/S-2.png 1280w" sizes="(max-width: 600px) 100vw, 600px" /></p>
<p style="padding-left: 40px;">(3) Click <span style="text-decoration: underline;">AMPTD</span>, Adjust the reference level, the scale and measurement time to better display the I/Q waveform on the screen.</p>
<p style="padding-left: 40px;"><img decoding="async" class="alignnone wp-image-41826" src="https://siglentna.com/wp-content/uploads/2024/01/S-3-1024x640.png" alt="" width="600" height="375" srcset="https://siglentna.com/wp-content/uploads/2024/01/S-3-1024x640.png 1024w, https://siglentna.com/wp-content/uploads/2024/01/S-3-300x188.png 300w, https://siglentna.com/wp-content/uploads/2024/01/S-3-768x480.png 768w, https://siglentna.com/wp-content/uploads/2024/01/S-3-600x375.png 600w, https://siglentna.com/wp-content/uploads/2024/01/S-3.png 1280w" sizes="(max-width: 600px) 100vw, 600px" /></p>
<p style="padding-left: 40px;">(4) Click <span style="text-decoration: underline;">Save/Recall</span>, save IQ data as .txt file.</p>
<p style="padding-left: 40px;"><img loading="lazy" decoding="async" class="alignnone wp-image-41827" src="https://siglentna.com/wp-content/uploads/2024/01/S-4-1024x640.png" alt="" width="600" height="375" srcset="https://siglentna.com/wp-content/uploads/2024/01/S-4-1024x640.png 1024w, https://siglentna.com/wp-content/uploads/2024/01/S-4-300x188.png 300w, https://siglentna.com/wp-content/uploads/2024/01/S-4-768x480.png 768w, https://siglentna.com/wp-content/uploads/2024/01/S-4-600x375.png 600w, https://siglentna.com/wp-content/uploads/2024/01/S-4.png 1280w" sizes="auto, (max-width: 600px) 100vw, 600px" /></p>
<h6></h6>
<h6><strong>2. IF Output</strong></h6>
<p style="padding-left: 40px;">The intermediate frequency (IF) output signal can be used for external signal processing and can be obtained via the ‘IF Out’ output connector on the instrument&#8217;s rear panel. Please note that the IF output is only useful in Zero Span.</p>
<p style="padding-left: 40px;">The IF Out signal, centered at approximately 120MHz, is simply a down-converted version of the RF Input signal that is present at the tuned frequency. The bandwidth of the IF output signal is approximately 40MHz. Requires Option SSA5000-IFO.</p>
<p><strong>2.1 Operation Demonstration</strong></p>
<p style="padding-left: 40px;">1）Input the RF signal to the RF port, and then output the IF signal through the IF Out connector on the rear panel.</p>
<p style="padding-left: 40px;">2）Click<span style="text-decoration: underline;"> FREQ</span>, configure the center frequency corresponding to the RF signal and turn on the Zero Span mode.</p>
<p style="padding-left: 40px;"><img loading="lazy" decoding="async" class="alignnone wp-image-41828" src="https://siglentna.com/wp-content/uploads/2024/01/S-5-1024x640.png" alt="" width="600" height="375" srcset="https://siglentna.com/wp-content/uploads/2024/01/S-5-1024x640.png 1024w, https://siglentna.com/wp-content/uploads/2024/01/S-5-300x188.png 300w, https://siglentna.com/wp-content/uploads/2024/01/S-5-768x480.png 768w, https://siglentna.com/wp-content/uploads/2024/01/S-5-600x375.png 600w, https://siglentna.com/wp-content/uploads/2024/01/S-5.png 1280w" sizes="auto, (max-width: 600px) 100vw, 600px" /></p>
<p style="padding-left: 40px;">3）Click <span style="text-decoration: underline;">Input/Output</span>, turn on the IF Out function.</p>
<p style="padding-left: 40px;"><img loading="lazy" decoding="async" class="alignnone wp-image-41829" src="https://siglentna.com/wp-content/uploads/2024/01/S-6-1024x640.png" alt="" width="600" height="375" srcset="https://siglentna.com/wp-content/uploads/2024/01/S-6-1024x640.png 1024w, https://siglentna.com/wp-content/uploads/2024/01/S-6-300x188.png 300w, https://siglentna.com/wp-content/uploads/2024/01/S-6-768x480.png 768w, https://siglentna.com/wp-content/uploads/2024/01/S-6-600x375.png 600w, https://siglentna.com/wp-content/uploads/2024/01/S-6.png 1280w" sizes="auto, (max-width: 600px) 100vw, 600px" /></p>
<p style="padding-left: 40px;">4）Use another spectrum analyzer to observe the IF signal. Configure the center frequency to 120MHz and the span to 50MHz.</p>
<p style="padding-left: 40px;"><img loading="lazy" decoding="async" class="wp-image-41830 alignnone" src="https://siglentna.com/wp-content/uploads/2024/01/S-7-1024x640.png" alt="" width="600" height="375" srcset="https://siglentna.com/wp-content/uploads/2024/01/S-7-1024x640.png 1024w, https://siglentna.com/wp-content/uploads/2024/01/S-7-300x188.png 300w, https://siglentna.com/wp-content/uploads/2024/01/S-7-768x480.png 768w, https://siglentna.com/wp-content/uploads/2024/01/S-7-600x375.png 600w, https://siglentna.com/wp-content/uploads/2024/01/S-7.png 1280w" sizes="auto, (max-width: 600px) 100vw, 600px" /></p>
<p style="text-align: left; padding-left: 40px;">IF Output when input an 1GHz RF signal</p>
<p style="padding-left: 40px;"><img loading="lazy" decoding="async" class="alignnone wp-image-41831" src="https://siglentna.com/wp-content/uploads/2024/01/S-8-1024x640.png" alt="" width="600" height="375" srcset="https://siglentna.com/wp-content/uploads/2024/01/S-8-1024x640.png 1024w, https://siglentna.com/wp-content/uploads/2024/01/S-8-300x188.png 300w, https://siglentna.com/wp-content/uploads/2024/01/S-8-768x480.png 768w, https://siglentna.com/wp-content/uploads/2024/01/S-8-600x375.png 600w, https://siglentna.com/wp-content/uploads/2024/01/S-8.png 1280w" sizes="auto, (max-width: 600px) 100vw, 600px" /></p>
<p style="text-align: left; padding-left: 40px;">IF Output when input a 3.5 GHz NR signal</p>
<p style="padding-left: 40px;">
<p>The post <a href="https://siglentna.com/operating-tip/ssa5000a-iqaifo-operation-manual/">SSA5000A IQA&#038;IFO Operation Manual</a> appeared first on <a href="https://siglentna.com">Siglent</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to protect sensitive RF instrumentation</title>
		<link>https://siglentna.com/operating-tip/how-to-protect-sensitive-rf-instrumentation/</link>
		
		<dc:creator><![CDATA[daisy]]></dc:creator>
		<pubDate>Thu, 05 May 2022 19:32:21 +0000</pubDate>
				<guid isPermaLink="false">https://siglentna.com/?post_type=operating-tips&#038;p=27893</guid>

					<description><![CDATA[<p>Spectrum and vector network analyzers like the SIGLENT SSA, SVA, and SNA series products feature very sensitive circuitry that can be easily damaged by electrostatic discharge or ESD. In many cases, ESD events aren&#8217;t obvious. It isn&#8217;t always a visible/noticeable event like the &#8220;wool sock shock&#8221; you may have tried as a child. ESD events &#8230; <a href="https://siglentna.com/operating-tip/how-to-protect-sensitive-rf-instrumentation/">Continued</a></p>
<p>The post <a href="https://siglentna.com/operating-tip/how-to-protect-sensitive-rf-instrumentation/">How to protect sensitive RF instrumentation</a> appeared first on <a href="https://siglentna.com">Siglent</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Spectrum and vector network analyzers like the SIGLENT SSA, SVA, and SNA series products feature very sensitive circuitry that can be easily damaged by electrostatic discharge or ESD. In many cases, ESD events aren&#8217;t obvious. It isn&#8217;t always a visible/noticeable event like the &#8220;wool sock shock&#8221; you may have tried as a child. ESD events often go unnoticed.</p>
<p>ESD events that occur near a sensitive RF circuit can cause:</p>
<ul>
<li>Complete loss of measurement capability. This can be verified visually. There may be no trace changes on the display when a known good signal is delivered to the input, etc..</li>
<li>Increased amplitude measurement error. The additional error could cause the readings to be higher or lower than expected.. from 0.1 dB to 10&#8217;s of dB.</li>
<li>Increased tracking generator/stimulus source error.</li>
</ul>
<p>Instrument designers include ESD prevention and protection in their designs, but this can only minimize the risk of damage.</p>
<p>Here are some steps you can implement to further minimize ESD events when working with sensitive circuitry:</p>
<ol>
<li>Maintain a relative humidity above 40%. Low humidity increases the likelihood of ESD events.</li>
<li>Short the center pin and outer shield of cables to neutralize any potential differences before connecting the cable to any sensitive input</li>
<li>Use proper ESD protection when working with input connectors or sensitive boards. Basic protection includes using a 1 MOhm resistor-isolated ESD wrist strap and ESD minimized work surfaces.</li>
<li>Always use properly grounded power outlets and power cords</li>
</ol>
<p>You can learn more at https://www.esda.org/</p>
<p>The post <a href="https://siglentna.com/operating-tip/how-to-protect-sensitive-rf-instrumentation/">How to protect sensitive RF instrumentation</a> appeared first on <a href="https://siglentna.com">Siglent</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RoHS compliance</title>
		<link>https://siglentna.com/operating-tip/rohs-compliance/</link>
		
		<dc:creator><![CDATA[daisy]]></dc:creator>
		<pubDate>Tue, 28 Dec 2021 12:42:55 +0000</pubDate>
				<guid isPermaLink="false">https://siglentna.com/?post_type=operating-tips&#038;p=35161</guid>

					<description><![CDATA[<p>Many SIGLENT products are RoHS compliant to EU 2015/863. This is also known as RoHS 3 Check the datasheet for the product in question to find more information.</p>
<p>The post <a href="https://siglentna.com/operating-tip/rohs-compliance/">RoHS compliance</a> appeared first on <a href="https://siglentna.com">Siglent</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Many SIGLENT products are RoHS compliant to EU 2015/863. This is also known as <a href="https://www.rohsguide.com/rohs3.htm" target="_blank" rel="noopener">RoHS 3</a></p>
<p>Check the datasheet for the product in question to find more information.</p>
<p>The post <a href="https://siglentna.com/operating-tip/rohs-compliance/">RoHS compliance</a> appeared first on <a href="https://siglentna.com">Siglent</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
