SDS6000A Digital Storage Oscilloscope

  • 500 MHz, 1 GHz, 2 GHz models
  • 5 GSa/s (10 GSa/s ESR) ADC per analog channel
  • Record Length up to 500 Mpts
  • Waveform capture rate up to 750,000 wfm/s (Sequence mode)
  • Eye diagram, Jitter analysis, Power analysis, Bode plot, decode, MSO, AWG
  • SAP2500, SAP2500D, 2.5 GHz active single ended and differential probes

Product Overview

SIGLENT’s SDS6000A series Digital Storage Oscilloscopes are available in bandwidths of 2 GHz, 1 GHz, and 500 MHz, have a sample rate of 5 GSa/s (10 GSa/s ESR) at each channel, a maximum record length of 500 Mpts, and display up to 4 analog channels + 16 digital channels mixed-signal analysis ability.

The SDS6000A series employs Siglent’s SPO technology with a maximum waveform capture rate of up to 170,000 wfm/ s (normal mode, up to 750,000 wfm/s in Sequence mode), 256-level intensity grading display function plus a color temperature display mode. It also employs an innovative digital trigger system with high sensitivity and low jitter. The trigger system supports multiple powerful triggering modes including serial bus triggering. Tools such as History waveform recording, Search and Navigate functions, Mask Test, Bode Plot, Power Analysis, and Eye/Jitter Analysis allow for extended waveform records to be captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a 25 MHz arbitrary waveform generator, as well as serial decoding are also features of the SDS6000A Digital Oscilloscope.

The large 12.1” display capacitive touch screen supports multi-touch gestures, with the addition of user-friendly UI design, which can greatly improve the operation efficiency. It also supports mouse control and remote web control over LAN.

Having trouble deciding which scope is right for you?

Click to view a comparison table of our most powerful scopes.

Bandwidth Channels Real time
sampling rate
Capture rate Memory depth Price
SDS6054A 500 MHz 4 + EXT 5 GSa/s (10 GSa/s ESR) per channel Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s 500 Mpts Call for quote Request a Quote
SDS6104A 1 GHz 4 + EXT 5 GSa/s (10 GSa/s ESR) per channel Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s 500 Mpts Call for quote Request a Quote
SDS6204A 2 GHz 4 + EXT 5 GSa/s (10 GSa/s ESR) per channel Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s 500 Mpts Call for quote Request a Quote
Limited Time Offer

   With the purchase of a new SIGLENT Performance Oscilloscope, purchase an Analysis Bundle at a special price

Key Features

  • 4 analog channels, up to 2 GHz bandwidth with 5 GSa/s (10 GSa/s ESR) sample rate at each channel
  • Low background noise, supports 0.5 mV/div to 10 V/div vertical scales
  • SPO technology
    • Waveform capture rates up to 170,000 wfm/s (normal mode), and 750,000 wfm/s (sequence mode)
    • Supports 256-level intensity grading and color temperature display modes
    • 500 Mpts Record length in total for all 4 channels
    • Digital trigger system
  • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/Hold, Delay, and Video (HDTV supported). Zone Trigger simplifies advanced triggering
  • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, and Manchester
  • Segmented acquisition (Sequence) mode, dividing the maximum record length into multiple segments (up to 80,000), according to trigger conditions set by the user, with a very small dead time between segments to capture the qualifying event
  • History waveform record (History) function, the maximum recorded waveform length is 80,000 frames
  • Automatic measurements on 50+ parameters supports statistics  with  histogram, track, trend, Gating measurement, and measurements on Math, History, and Ref
  • 4 Math traces (8 Mpts FFT, addition, subtraction, multiplication, division, integration, differential, square root, etc.), supports formula editor
  • Abundant data analysis functions such as Search, Navigate, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis and Eye/Jitter Analysis
  • High-Speed hardware-based Average, Hi-Res; High Speed hardware-based Mask Test function, with Mask Editor tool for creating user-defined masks
  • 16 digital channels (optional)
  • 25 MHz function / arbitrary waveform generator, built-in multiple predefined waveforms
  • Large 12.1” TFT-LCD display with 1280 * 800 resolution; Capacitive touch screen supports multi-touch gestures
  • Interfaces include: USB Hosts, USB Device (USBTMC), LAN(VXI-11/Telnet/Socket), micro SD card, Pass/Fail, Trigger Out, HDMI
  • Built-in web server supports remote control over the LAN port using a web browser. Supports SCPI remote control commands. Supports external mouse and keyboard

Need more information? Call us now 877-515-5551

Product Characteristics

Achieve more View more

Achieve more

Achieve more

Flexible: The SIGLENT SDS6000A oscilloscope is available in 500 MHz, 1 GHz, and 2 GHz models. To protect your investment, the 500 MHz and 1 GHz bandwidths can be upgraded to 2 GHz.

SDS6000A comes with even more memory depth. 500 Mpts and a hardware-based zoom.

The sample rate is up to 5 GSa/s (10 GSa/s ESR) per channel, even when you use all four channels at the same time. No compromises.

.

Eye diagram and Jitter Analysis View more

Eye diagram and Jitter Analysis

Eye diagram and Jitter Analysis

Troubleshoot high-speed digital circuits more effectively using the Jitter Analysis option.

Delivers Eye Diagram and Jitter analysis including jitter decomposition information and more.

Modern form factor balances ease-of-use and desk space View more

Modern form factor balances ease-of-use and desk space

Modern form factor balances ease-of-use and desk space

The SDS6000A is easy to move around the lab and occupies a small amount of desk space. The big 12.1 inch and high-resolution touch screen provide intuitive control and clear information for faster debugging.

Save data on SDS6000A is also convenient. Just press the Print button or take a screenshot via remote web server.

It is also easily customized, you can choose your favorite channel traces colors, default settings, menu styles, and measurement formats. The faster UI response of SDS6000A makes R&D work even more pleasing.

Newly designed active probes View more

Newly designed active probes

Newly designed active probes

For high-speed digital/fast rise time measurements, an active probe is the perfect choice. The standard SIGLENT SAP1000 active probe is fully compatible with the SDS6.. but there are also two new active probes. SAP2500 is single-ended and the  SAP2500D is 2.5 GHz differential active probe. With the Eye diagram/ Jitter analysis functions, SDS6000A is more capable in high-speed circuits design and signal integrity measurements.

Standard Accessories

USB Cable

USB Cable

SP3150A 500 MHz Oscilloscope Probe

Certificate of calibration – SDS6000A

SDS6000A Quick Start

Wireless Mouse

Protective Cover

Protective Cover for Oscilloscopes and VNAs

Support and Resources

Application Notes

Bode Plot of a filter using an oscilloscope and function generator

Download PDF A Bode plot is a method of graphically displaying the frequency response of a system or device-under-test (DUT). Commonly, the magnitude and phase response of the device are plotted with respect to frequency using a shared horizontal frequency axis as shown in the example below:   By showing both the magnitude and phase … Continued

Generating an Activation Code (Option Code)

Download PDF Introduction Many SIGLENT products have options that can be activated by entering a special activation code into the front panel. This note covers how to generate the activation code.   Setup Contact your Authorized SIGLENT sales office or distributor to obtain an Option Card. This is typically a document that is emailed as … Continued

Analyzing GSM Radio Protocol with a Siglent SDS2000X Plus Oscilloscope

Download PDF Two SIGLENT users, Karel and Simon Sotek, email2@avanaconsulting.de recently took a SIGLENT SDS2354X Plus oscilloscope and investigated a GSM cell phone signal. Here is their report: We took a retired Siemens A36 cellphone to learn the capabilities of this new Siglent scope. Available documentation and medium-density PCB of the selected A36 made the … Continued

Welcome to SIGLENT North America.
Please select a website to continue

CN