SDL1000X/X-E Series Programmable DC Electronic Loads

  • SDL1020X (Single channel ): DC 150 V/30 A, total power up to 200 W
  • SDL1030X (Single channel ): DC 150 V/30 A, total power up to 300 W
  • 4 static modes / Dynamic mode: CC/CV/CR/CP
  • Min. readback resolution: 0.1 mV, 0.1 mA
  • Adjustable current rise time range: 0.001 A/us~2.5 A/us

Product Overview

SDL1000X/SDL1000X-E series Programmable DC Electronic Loads have a 3.5 inch TFT-LCD display, a user-friendly interface and superb performance specifications. SDL1020X/SDL1020X-E DC Electronic Loads feature an input range of 150 V/30 A 200 W while the SDL1030X/SDL1030X-E have an input range of 150 V/30 A 300 W. The SDL1000X series leads with measurement resolution of 0.1 mV/0.1 mA and the base SDL1000X-E series resolution is 1 mV/1 mA and adjustable current rise times from 0.001 A/μs~2.5 A/μs. For remote communication and control, the SDL series includes RS232/USB/LAN interface types. SDL1000X electronic loads deliver stability over a wide range of applications and can meet all kinds of testing requirements, including: Power, battery/handheld device design, industry, LED lighting, automotive electronics.

Series Input voltage/current/power Mode CC Dynamic mode frequency Measuring speed Current Slew Rate Min. readback resolution Price
SDL1020X-E 150 V/30 A 200 W CC/CV/CR/CP 25 kHz up to 500 kHz 0.001 A/us~2.5 A/us 1 mV, 1 mA $499 Buy Now
SDL1020X 150 V/30 A 200 W CC/CV/CR/CP 25 kHz up to 500 kHz 0.001 A/us~2.5 A/us 0.1 mV, 0.1 mA $695 Buy Now
SDL1030X-E 150 V/30 A 300 W CC/CV/CR/CP 25 kHz up to 500 kHz 0.001 A/us~2.5 A/us 1 mV, 1 mA $880 Buy Now
SDL1030X 150 V/30 A 300 W CC/CV/CR/CP 25 kHz up to 500 kHz 0.001 A/us~2.5 A/us 0.1 mV, 0.1 mA $1,145 Buy Now

Key Features

  • SDL1020X (Single channel ): DC 150 V/30 A, total power up to 200 W
  • SDL1030X (Single channel ): DC 150 V/30 A, total power up to 300 W
  • 4 static modes / Dynamic mode: CC/CV/CR/CP
  • CC Dynamic mode: Continuous, pulsed, toggled
  • CC Dynamic mode: 25 kHz, CP Dynamic mode: 12.5 kHz, CV Dynamic mode: 0.5 Hz
  • Measuring speed of voltage and current: up to 500 kHz
  • Adjustable current rise time range: 0.001 A/us~2.5 A/us
  • Min. readback resolution: 0.1 mV, 0.1 mA
  • Short-circuit, Battery test, CR-LED mode, and factory test functions
  • 4-wire SENSE compensation mode function
  • List function supports editing as many as 100 steps
  • Program function supports 50 groups of steps
  • OCP, OVP, OPP, OTP and LRV protection
  • External analog control
  • Voltage, Current monitoring via 0-10 V
  • 3.5 inch TFT-LCD display, capable of displaying multiple parameters and states simultaneously
  • Built-in RS232/USB/LAN communication interface, USB-GPIB module (optional)
  • Waveform trend chart and easy-to-use file storage and call functions
  • Includes PC software: Supports SCPI, LabView driver

Just finished some LiPo charger characterization with your new DC Electronic Load instrument. I would say any engineer designing battery chargers for portable devices needs to have one of these on their bench! Worked great and very intuitive. Great job! -Mark W.

Need more information? Call us now 877-515-5551

Product Characteristics

Steady state operating mode View more

Steady state operating mode

Steady state operating mode

The SDL features four operating modes to provide flexible test capabilities. In CC mode, the electronic load will sink a constant current, regardless of the voltage at its terminals. In CV mode, the electronic load will cause a constant voltage to appear at its terminals. In CR mode, the electronic load will behave as a fixed resistance value. As shown in the figure, the electronic load will linearly change the current according to the input voltage. In CP mode, the electronic load will cause a constant power to be dissipated in the load.

Dynamic test mode up to 25 kHz (CC) View more

Dynamic test mode up to 25 kHz (CC)

Dynamic test mode up to 25 kHz (CC)

The transient test allows switching between two different load values. A common application is to test the dynamic characteristics of a DC source or DUT (Device-Under- Test). The transient test function enables the load to periodically switch between two set levels (Level A and Level B). The highest frequency can be set to 25 kHz in CC mode. The highest frequency can be set to 12.5 kHz in CP modes.

Simplify complex sequencing using the list operation function View more

Simplify complex sequencing using the list operation function

Simplify complex sequencing using the list operation function

You can generate complex load sequences quickly using the list operation function. Here, you can edit the setpoints, dwell time, and slew rate for each step in the test. *Slew rate can only be edited in CC mode.

Electronic Load list operating function

4-wire SENSE compensation mode function View more

4-wire SENSE compensation mode function

4-wire SENSE compensation mode function

In CC/CV/CR/CW mode, when a load is connected to a power supply, it will cause a large voltage-drop on the connection lines between tested instrument and terminals of load. Using remote sense, you can measure the voltage at the DUTs input terminals, effectively removing the additional error due to the voltage drop in the connection wires.

Program function View more

Program function

Program function

In program (auto-test) mode, you can generate a sequence of tests using different modes, mode parameters and durations. This function is useful for automatically executing a set of tests on a device then display whether the tests passed or failed. Test results are easily viewed by pressing the up and down buttons. The load provides 8 nonvolatile registers to save auto-test file for recall later. Each file contains 1-50 steps to set up. Auto-test function is especially useful in the designing battery charging circuitry.

Battery discharge function View more

Battery discharge function

Battery discharge function

The SDL1000X DC Electronic Load can also provide insight into battery performance by analyzing the discharge characteristics of the DUT. The SDL features three stop conditions for the discharge test: Voltage, capacity or time. The discharge process is immediately terminated if the stop conditions are met. This provides more control over the test termination and an extra layer of safety during critical tests. Throughout the test process the battery voltage, discharge current, discharge time and discharged capability is displayed clearly on the LCD panel.

OCPT/OPPT Mode View more

OCPT/OPPT Mode

OCPT/OPPT Mode

Over-current protection (OCPT) mode prevents drawing too much current from the DUT. After the input voltage reaches the Von point, the DC load will start to draw a current from the source after a delay time. The current value will increase by a certain step size at regular intervals. Simultaneously, the DC load will compare the input voltage to the OCP voltage:If it is lower, then the present current value will be compared to see if it is in the current range you have set. Within the range, the OCP test will evaluate Pass or Fail. If it is outside of the set range, the DC load will to increase drawing current and compare the voltage again.

Overpower-protection (OPPT) mode: When the input voltage has reached the Von point, the load will draw power after a delay time. The power value will increase by a step size at regular intervals. Simultaneously, the DC load will judge whether the input voltage is lower than OPP voltage you have set, if it is, then the present current value will be compared to see if it is in the current range you have set. Within the range, the OPP test will Pass or Fail. If it is outside of the set power, the load will continue to increase the power draw within the cut-off current range and compare OPP voltage with the input.

CR-LED Mode View more

CR-LED Mode

CR-LED Mode

The SDL1000X electronic load includes a CR-LED mode specifically for LED driver testing. Basing on the traditional CR mode, CR-LED mode adds a diode breakover voltage setting. When the input voltage is above this set value, the DC load start to work. Thus, it can emulate the actual characteristics of an LED.

Voltage Rise/Fall speed test View more

Voltage Rise/Fall speed test

Voltage Rise/Fall speed test

The DC electronic load is also equipped to directly measure voltage rise and fall times. It can calculate the time from one voltage to another without the need for additional measurement instrumentation. With an SDL1000X, you can save money and improve effciency.

Voltage threshold function View more

Voltage threshold function

Voltage threshold function

Siglent SDL1000X can be set to turn on or off if the input voltage is at, above, or below a set value. By defining these thresholds, you control when the load is active. Which minimizes test time and increases safety.

Waveform trend chart function View more

Waveform trend chart function

Waveform trend chart function

The electronic load includes a waveform display function and supports the following operations for the waveform: Pause, recording, and capturing the waveform. You can quickly observe the trends of parameter changes as they occur throughout the test.

Save/Recall setting parameters View more

Save/Recall setting parameters

Save/Recall setting parameters

The load allows you to save different types of fles to the internal and external memories. You can recall and read them when necessary.

External analog control View more

Save/Recall setting parameters

External analog control

The load allows the user to control current or voltage through external analog terminals (EXT PRG). Input a 0-10 V analog to adjust 0-100% rated voltage and current. It is very useful for those applications that need to change the input value with external signals.

Multiple protection modes View more

Save/Recall setting parameters

Multiple protection modes

The SDL1000X series Programmable DC Electronic Load provides five protection types: OVP, OCP, OPP, OTP and LRV. When OVP/OCP/OPP/OTP/reverse voltage protection (LRV) occurs, the load will immediately turn off the input and stop sinking. Then, a prompt message is displayed.

Standard Accessories

USB Cable

USB Cable

Quick Start-SDL1000X

Optional Accessories

Support and Resources

Application Notes

Power Supply Design: Load Step Response with a SIGLENT DC Electronic Load

Download PDF Building a power supply that can handle various loads without oscillating can be a challenge. Computational models and computer simulations can help get your design headed in the right direction, but physical testing is essential to proving the performance of your design. One method of quickly determining stability is to use a load … Continued

Testing Intrinsic Safety Barrier fusing and circuitry using an electronic load

Download PDF From Wikipedia: Intrinsic safety (IS) is a protection technique for safe operation of electrical equipment in hazardous areas by limiting the energy, electrical and thermal, available for ignition. The idea is to minimize the risk of fire or explosion by physically eliminating any potential source of ignition. Many IS circuits utilize special fusing and elements that are … Continued

Programming Example: Identification String (*IDN?) return with LabVIEW 2018

Download PDF This LabVIEW VI (version 2018) provides a simple platform to begin creating LabVIEW programs. You can download the VI here: VISA_IDN.ZIP In this example, the user can: Select the connected instruments from the VISA Resource List drop down menu: NOTE: USB devices will automatically appear. For LAN connections, you will need to add … Continued

Welcome to SIGLENT North America.
Please select a website to continue