Saving and Recalling a Bode II Setup
October 5, 2022
Many SIGLENT oscilloscopes, including the SDS1104/1204X-E, SDS2000X-E, SDS2000X Plus, SDS2000X HD, SDS5000X, and SDS6000A series feature the built-in Bode II automated Bode plotting feature. When coupled with a SIGLENT SDG series generator or SAG external AWG, the scope/generator combo can be used to produce frequency response curves on many circuit elements and components as well as … Continued
SDG Function generator output amplitude is double the setpoint when I modulate the output. Is this OK?
February 16, 2022
This is expected. When the AM depth is 0%, the output amplitude is the carrier’s amplitude. When the AM depth is 100%, the amplitude of the modulated waveform will be 2x the setpoint.
Common Fuse Information
February 9, 2022
Fuses are a common circuit element and are key to protecting from overvoltage and overcurrent situations that can damage important circuits. Fuse markings are typically stamped symbols located on the metal cap of the fuse. Here is a helpful guide to common fuse markings used with instrumentation, taking a common fuse type as an example: … Continued
RoHS compliance
December 28, 2021
Many SIGLENT products are RoHS compliant to EU 2015/863. This is also known as RoHS 3 Check the datasheet for the product in question to find more information.
SDG remote SCPI command to request a screen image
December 22, 2021
The SDG800, SDG1000, SDG1000X, SDG2000X, and SDG6000X can return bitmap images of their displays by sending the following command: SCDP
SDG remote SCPI command to request a screen image
December 22, 2021
The SDG800, SDG1000, SDG1000X, SDG2000X, and SDG6000X can return bitmap images of their displays by sending the following command: SCDP
Do your instruments support UDP communications over LAN?
August 5, 2021
Not at this time. Many instruments support communication via sockets (port 5025) and telnet (port 5024) but the port numbers cannot be changed. If you use VISA, you can implement LAN via TCP/IP, which does not need a port number. Here is a listing of current SIGLENT instruments with Socket and Telnet Support.
SDG available waveform lengths
July 29, 2021
The SDG series of arbitrary waveform generators allow you to create any function you wish. Here are the memory depths available for building arbs for each model:
How to check available internal memory?
July 29, 2021
Simply access the Save/Recall menu for the instrument in question and select Local. The menu will show used/total amounts. Here, the SDG6X has approximately 83 MB and the SDG1X has 85 MB of memory:
How do I find the Spurious Free Dynamic Range (SFDR) for an SDG function generator?
May 21, 2021
If the SFDR is not listed directly in the specifications, you can find it by selecting the largest value between the harmonic and non-harmonic spurious data from the specification sheet at the frequency of interest. For example, here is the SDG6X generator specs for harmonic and non-harmonic distortion: If the signal of interest was … Continued