SSA3000X Series Spectrum Analyzers

  • All-Digital IF Technology
  • Frequency Range from 9 kHz to 2.1/3.2 GHz
  • -161 dBm/Hz Displayed Average Noise Level (Typ.)
  • -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.)
  • Total Amplitude Accuracy < 0.7 dB
  • 1 Hz Minimum Resolution Bandwidth (RBW)
  • Tracking generator (TG) is currently included at no charge

Product Overview

Siglent SSA3000X Spectrum Analyzers offer a frequency range of 9 KHz to 2.1/3.2 GHz. With their light weight, small size, and friendly user interface, the SSA3000X present a large, bright, easy to read display, powerful and reliable automatic measurements, and plenty of impressive features.

SSA3000X Spectrum Analyzers’ applications include research and development, education, production, maintenance, and pre-compliance testing.

For a full summary of our RF measurement instruments, view our Spectrum Analyzer Features and Options Tables.

Frequency Range Resolution Bandwidth (RBW) Phase Noise Total Amplitude Accuracy Display Average Noise Level (DANL) Price
SSA3021X 9 kHz to 2.1 GHz 1 Hz to 1 MHz, in 1-3-10 sequence < -98 dBc/Hz @ 1 GHz, 10 kHz offset ± 0.7 dB -161 dBm/Hz, Normalized to 1 Hz (typ.) $1395 Buy Now
SSA3032X 9 kHz to 3.2 GHz 1 Hz to 1 MHz, in 1-3-10 sequence < -98 dBc/Hz @ 1 GHz, 10 kHz offset ± 0.7 dB -161 dBm/Hz, Normalized to 1 Hz (typ.) $2595 Buy Now

Key Features

  • Standard Preamplifier
  • Standard Tracking Generator Kit (Included)
  • Reflection/VSWR Measurement Kit (Opt.*)
  • Advanced Measurement Kit/Waterfall Chart (Opt.*)
  • EMI Pre-compliance Measurements Kit (Opt.*)
  • 10.1 lnch WVGA (1024 x 600) Display

*New SSA3000X analyzers feature approximately 40 hours of free trials of these options. The trial timer is running when the instrument is powered on. After the trial has expired, the function will be disabled/greyed out.

Please continue to provide quality gear at reasonable prices. I am impressed with Siglent’s equipment and the engineering behind them. 

Bill H.

May, 2018

Need more information? Call us now 877-515-5551

Product Characteristics

Easy to operate, Support four independent traces and cursors View more

Easy to operate, Support four independent traces and cursors

Easy to operate, Support four independent traces and cursors

Four selectable color-coded traces can be used for different functions (ie. Max Hold, Min Hold, Clear-Write, Math, Average, etc)

Four movable markers.

1 Hz Minimum Resolution Bandwidth (RBW) View more

1 Hz Minimum Resolution Bandwidth (RBW)

1 Hz Minimum Resolution Bandwidth (RBW)

RBW: 1 Hz – 1 MHz in 1-3-10 sequence.
(Minimum RBW depends on Frequency Span)

Noise Level View more

Noise Level

Noise Level

-151 dBm Displayed Average Noise Level (RBW=10 Hz).

Phase noise View more

Phase noise

Phase noise

Phase noise -98 dBc/Hz @ 1 GHz @ 10 kHz offset.

Zero span and demodulation capabilities View more

Zero span and demodulation capabilities

Zero span and demodulation capabilities

SSA3000X Spectrum Analyzer AM/FM demodulation with audio output jack.

Advanced measurement kit View more

Advanced measurement kit

Advanced measurement kit

AMK-SSA3000X includes on-screen ACPR measurements. Channel power, Adjacent channel power ratio, TIme domain power, Occupied BW, Third-order intercept, Spectrum monitor (waterfall).

On-screen VSWR/Return Loss measurements View more

On-screen VSWR/Return Loss measurements

On-screen VSWR/Return Loss measurements

On-screen VSWR/Return Loss measurements with the reflection measurement option (REFL-SSA3000X). Available with or without directional coupler.

EMI filters and Quasi-Peak detector View more

EMI filters and Quasi-Peak detector

EMI filters and Quasi-Peak detector

EMI filters and Quasi-Peak detector following CISPR 16 (EMI-SSA3000X). Comes with EMI report software. Speeds measurement time, generates test reports.

Standard Accessories

USB Cable

USB Cable

Quick Start Guide-SSA

TG-SSA3000X

Support and Resources

Application Notes

Analyzer Features and Options Table

Download PDF Selecting the proper instrument for your application can be challenging. Here are tables that identify key features and options of SIGLENTs analyzer products to help you choose exactly what you need:   SIGLENT Analyzer Features:   SIGLENT Analyzer Options:   Tracking Generator included free with all SSA3000X, Plus, SVA, and X-R series analyzers … Continued

Electromagnetic Compliance: Pre-Compliance Test Basics

Download PDF Today’s products are subjected to more standardized test requirements than ever before. These standards (UL, CE, and others) ensure consumer safety and add to the quality and dependability of products. But, these tests also add cost to the manufacturer, which is passed to the consumer. This is especially true with electronics. Any product … Continued

Electromagnetic Compliance: Pre-Compliance Conducted Emissions Testing

Download PDF Electromagnetic compliance (EMC) testing involves measuring the radio frequency (RF) output of a product and comparing the results to published limits that are set forth by a government agency responsible for creating and enforcing standards, such as the Federal Communications Committee (FCC) in the United States. Any product that has the ability to … Continued

Welcome to SIGLENT North America.
Please select a website to continue