Application Notes

SDS2000X-E Series

How to Extract Data from the Binary File of Siglent Oscilloscope

June 12, 2024

Data can be formatted in many different ways. Binary data formatting often provides the smallest payload size and therefore transfers via USB/LAN more quickly. Unfortunately, binary is very difficult to interpret by humans. So, binary data is often reformatted to other types (ASCII, etc..)/ Here is a link to the binary data format for many … Continued

SLA1016 Mixed Signal Oscilloscope Whitepaper

April 26, 2023

About the Author Mike Cardoso is a controls engineer working for a leader in the industrial automation sector, primarily focused on motion control and variable frequency drive (VFD) technology. In his free time Mike has a passion for industrial robotics, electrical design and test, and machining and has a home shop for pursuing these activities. … Continued

Baltic Labs: Generate a stereo-FM multiplex waveform with Python and AWG

October 20, 2022

Sebastian @ Baltic Labs had a recent project that required a stereo-FM multiplex (MPX) signal containing two different tones in the left and right stereo audio channels. This article shows how to generate such an MPX signal for Siglent SDG-series arbitrary waveform generators with Python and PyVISA. Generate a stereo-FM multiplex waveform with Python and … Continued

Jitter spectrum measurements with a digital oscilloscope

February 21, 2022

Clockworks Signal Processing released an application note that measures jitter using a SIGLENT XE series of oscilloscopes. The basic idea is simple enough – measure the clock edges and see if they are all exactly evenly spaced or if they change (jitter) over time. A non-uniform clock fed to an ADC or DAC will produce … Continued

Oscilloscope Feature and Options Table

January 11, 2022

SIGLENT has a number of oscilloscopes to help fit your application needs and budget. Here is a table of features and options of our most powerful oscilloscopes to help decide what is best for you. S – Standard, included O – Optional  (1) – Bode requires a SIGLENT SAG, SDG, or internal function generator to … Continued

Power Supply Design: Load Step Response with a SIGLENT DC Electronic Load

April 3, 2020

Building a power supply that can handle various loads without oscillating can be a challenge. Computational models and computer simulations can help get your design headed in the right direction, but physical testing is essential to proving the performance of your design. One method of quickly determining stability is to use a load step response. … Continued

Programming Example: Identification String (*IDN?) return with LabVIEW 2018

December 16, 2019

This LabVIEW VI (version 2018) provides a simple platform to begin creating LabVIEW programs. You can download the VI here: VISA_IDN.ZIP In this example, the user can: Select the connected instruments from the VISA Resource List drop down menu: NOTE: USB devices will automatically appear. For LAN connections, you will need to add the device. … Continued

Measuring Power Supply Control Loop Response with Bode Plot II

May 24, 2019

Introduction Stability is one of the most important characteristics in power supply design. Traditionally, stability measurements require expensive frequency response analyzers (FRA) which are not always available in a laboratory. SIGLENT has released Bode Plot Ⅱ features to the SIGLENT SDS1104X-E, SDS1204X-E, SDS2000X-E, SDS2000X Plus, SDS5000X, and SDS6000A series of oscilloscopes. When combined with a … Continued

Welcome to SIGLENT North America.
Please select a website to continue

LV